COMPARISON OF LEDs TO OTHER LIGHTING SYSTEMS (each lighting system at a rated 100 watts)
| TYPE |
LUMENS |
LUM/WATT
EFFICACY
|
MIN. START
TEMP.
|
25°C START
TIME (1)
|
AVG. LIFE (2) |
CCT |
| CFL |
6200 |
75 |
-20°C |
0.5 – 5 sec. |
10000 hrs. |
4200°K |
| HPS |
9500 |
95 |
-40°C |
3 – 4 min. |
24000 hrs. |
2200°K |
| INCAN |
1700 |
17 |
-40°C |
0.1 secs. |
750 hrs. |
2700°K |
| INDUCT |
7000 |
70 |
-40°C |
0.5 – 5 sec. |
50000 hrs. |
3000°K |
| LPS |
14200 |
142 |
-20°C |
7 – 10 min. |
16000 hrs. |
1700°K |
| MET HALIDE |
8500 |
85 |
-20°C |
2 – 5 min. |
15000 hrs. |
4000°K |
| MERC. VAP. |
4100 |
41 |
-30°C |
5 – 7 min. |
24000 hrs. |
3700°K |
| LED |
11000 |
110 |
-40°C |
Instant |
50000 hrs. |
2700°K – 6000°K |
Notes:
(1) Start time is time from initial power-on to full output with 25°C ambient temperature